Nickel sulfide (NiS) inclusion failure is characterized by a breakage pattern resembling a butterfly, figure-8, or back-to-back D (outlined in red). However, other types of inclusions, and even impact, can occasionally create similar patterns, so until the glass is analyzed, NiS inclusion should not be assumed.
Photo courtesy Hoffmann Architects, Inc.